Maytag refrigerator compartment not working (freezer works)
Symptom: No light in the fridge, compressor running.
Cause: Faulty thermostat.
Maytag refrigerator compressor not working
Symptom: Compressor silent, high temperature in compartments, control panel and lights functional.
Cause: Clogged capillary tube.
Maytag compressor turns on and off immediately
Symptom: Refrigerator starts, makes noise, then shuts down abruptly.
Cause: Compressor failure.
Maytag compressor runs non-stop
Symptom: Excessively low temperature in compartments, control panel active, light on, constant noise.
Cause: Thermostat malfunction.
Symptom: High temperature in compartments, compressor and lights functional, but food not chilled.
Maytag refrigerator not cooling
Cause: Broken control board.
Symptom: No sound, lights off, no cooling.
Maytag refrigerator not working
Maytag refrigerator won’t turn off
Symptom: Food over-freezes, compressor continues running after reaching target temperature.
Cause: Failed thermostat.
Maytag refrigerator won’t start
Symptom: Compartment temperatures above normal, light on, compressor inactive.
Cause: Likely compressor failure.
Upper compartment not cooling
Symptom: Refrigerator operational, but upper section not cold; compressor noisy.
Cause: Faulty evaporator.
Maytag refrigerator not chilling
Symptom: Unit running but compartments warm, compressor stays on.
Cause: Damaged door seal.
Maytag refrigerator fails to cool
Symptom: Temperatures not dropping to optimal levels, light on, compressor runs continuously.
Cause: Likely refrigerant leak.
Maytag refrigerator won’t start cooling cycle
Symptom: Light on, but compressor fails to circulate refrigerant.
Cause: Clogged capillary tube.
Frequent Maytag refrigerator breakdowns